Dorgard 1328-A01 Acoustic Fire Door Retainer

dorgard_red

  

Dorgard 1328-A01 

  • Installs in under 5 minutes
  • Battery operated, wire-free solution
  • 2 No. C size batteries included
  • Complies with BS EN 1155: 1997 and accepted by the Fire and Rescue Services
  • Complies with BS 72773-4: 2007 Category B - Actuation of Release Mechanisms for Doors
  • Improves access throughout buildings - in line with the Equalities Act 2010
  • Automatically releases when fire alarm sounds
  • Proven in thousands of buildings across the UK
  • Smart, unobtrusive design
  • Available in red, black and white
  • Easy foot-operated release and adjustment
  • Plunger, with rubber ferrule, grips onto floor (or optional floor plate) to hold door open
  • Batteries and fixings - included in price
  • Automatic night-time release
  • Improves access for wheelchair users in line with DDA

 

Dorgard 1328-A01 Fitting and Operating Guide 

 

 Dorgard Spares - Rubber Ferrules or Floor Plate 

 

We are the largest and longest established supplier of the Fire Brigade accepted door guard products - the Agrippa Holder, the Dorgard 1328-A01, the Smartsound acoustic fire door retainer and the unique Award Winning range of Kickstop reinforcing and anti-jemmy products to strengthen and reinforce timber doors and frames against 'kick-in' type burglaries.

 Tel: 01536 790999

Online B2B shop powered by Security Matters

 

Dorgard - 1328-A01 - Fire Door Retainer

 

Discounted Price

1-9 Units - £99.00 per unit

10+ Unit - £93.00 per unit


The Dorgard Acoustic Fire Door Retainer is the safe, reliable and smart choice for fire door retaining problems.

It's tempting to hold fire doors open with wedges or, ironically, fire extinguishers.  This is dangerous and could result in fire insurance becoming void and the personal prosecution of directors, partners or proprietors of offending businesses and organisations.

  • Complies fully with all relevant British Standards and EC Directives.
  • Tested to BS EN 1155 and accepted by the Fire Brigade.
  • Complies with BS 7273-4: 2015 Category 'Standard' - Actuation of Release Mechanisms for Doors

  • The Dorgard 1328-A01 can legally hold open fire doors which greatly improves access throughout buildings - in line with the Equalities Act 2010

  • 2 Year Warranty 

Dorgard 1328-A01 Black






The Dorgard Acoustic Fire Door Retainer is the safe, reliable and smart choice for fire door retaining problems.

It's tempting to hold fire doors open with wedges or, ironically, fire extinguishers.  This is dangerous and could result in fire insurance becoming void and the personal prosecution of directors, partners or proprietors of offending businesses and organisations.

  • Complies fully with all relevant British Standards and EC Directives.
  • Tested to BS EN 1155 and accepted by the Fire Brigade.
  • Complies with BS 7273-4: 2015 Category 'Standard' - Actuation of Release Mechanisms for Doors

  • The Dorgard 1328-A01 can legally hold open fire doors which greatly improves access throughout buildings - in line with the Equalities Act 2010

  • 2 Year Warranty

Dorgard 1328-A01 Red






The Dorgard Acoustic Fire Door Retainer is the safe, reliable and smart choice for fire door retaining problems.

It's tempting to hold fire doors open with wedges or, ironically, fire extinguishers.  This is dangerous and could result in fire insurance becoming void and the personal prosecution of directors, partners or proprietors of offending businesses and organisations.

  • Complies fully with all relevant British Standards and EC Directives.
  • Tested to BS EN 1155 and accepted by the Fire Brigade.
  • Complies with BS 7273-4: 2015 Category 'Standard' - Actuation of Release Mechanisms for Doors

  • The Dorgard 1328-A01 can legally hold open fire doors which greatly improves access throughout buildings - in line with the Equalities Act 2010

  • 2 Year Warranty

Dorgard 1328-A01 White






The Dorgard Acoustic Fire Door Retainer is the safe, reliable and smart choice for fire door retaining problems.

It's tempting to hold fire doors open with wedges or, ironically, fire extinguishers.  This is dangerous and could result in fire insurance becoming void and the personal prosecution of directors, partners or proprietors of offending businesses and organisations.

  • Complies fully with all relevant British Standards and EC Directives.
  • Tested to BS EN 1155 and accepted by the Fire Brigade.
  • Complies with BS 7273-4: 2015 Category 'Standard' - Actuation of Release Mechanisms for Doors

  • The Dorgard 1328-A01 can legally hold open fire doors which greatly improves access throughout buildings - in line with the Equalities Act 2010

  • 2 Year Warranty

Dorgard Rubber Ferrules

Packet Quantity Discounts

Each packet contains 5 Ferrules

  • Spare rubber Ferrules (feet) for Dorgard and Smartsound foot plunger

 

Dorgard & Smartsound FloorPlate Kit

Pack Quantity Discount

Pack of 1 standard plate with 'bump' stop and 1 additional 'anti-hazard' plate - with fixings and fitting instructions

  • Spare or replacement FloorPlate kit - with fixings

Dorgard & Smartsound FloorPlate with Bump Stop

Pack Quantity Discount

Pack of 1 spare or replacement standard Floor Plate with bump stop - with fixings and fitting instructions

Dorgard & Smartsound FloorPlate - Flat Anti-Hazard

Pack Quantity Discount

Pack of 1 spare or replacement flat Anti-Hazard Floor Plate with NO bump stop - with fixings and fitting instructions

Duracell Procell Batteries for Dorgard, Shuttle, Agrippa and Deafgard

  • Packet of TWO
  • For Dorgard, Smartsound and Agrippa Acoustic Fire Door Retainers
  • For Deafgard Acoustic bedside/pillow fire safety device
  • Duracell Procell C size (LR14) professional alkaline 1.5V batteries
  • Long lasting & high energy. Designed for commercial and industrial users.

Deafgard 1329-A01

Deaf and hard of hearing people are in danger of not hearing the fire alarm.

Deafgard is the safe, legal and cost effective solution.

  • Moveable, wire-free, acoustically-triggered bedside unit.

  • In the event of fire, a deaf or hard of hearing person will not be able to hear the fire alarm - especially when they are asleep in hotels, sheltered housing, care homes etc.  This is a high risk and life threatening situation and the Deafgard 1329-A01 is considered to be an excellent solution.

  • This safe, legal solution, offers the simplest and most cost-effective way of legally communicating the sounding of a fire alarm to deaf and hard of hearing people in hotel rooms and other residential premises.